When you need restaurant electrical
- New restaurant
- Equipment changes
- Breaker trips
- Inspection issues
- Remodel
Equipment circuits
Each appliance needs correct circuits.
Hood interlocks
Hoods and suppression systems are interlocked.
GFCI in kitchens
Commercial kitchens need GFCI protection.
Matching circuits to cooking equipment
Every piece of kitchen equipment lists its voltage, phase and current on the nameplate and in its spec sheet. Fryers, combi ovens, dish machines and walk-in condensers often need 208 or 240-volt circuits, and many need three-phase power. The electrician works from the equipment schedule produced by the kitchen designer, so circuits, receptacle types and cord-and-plug versus hardwired connections match what arrives on the truck.
Hood and fire-suppression interlocks
Commercial cooking hoods have a fire-suppression system that, when triggered, must shut off fuel and electric power to the cooking appliances beneath it. That is done with shunt-trip breakers or contactors wired to the suppression system’s release, plus fan controls so exhaust keeps running. The electrician coordinates with the hood installer and the suppression contractor, and the fire marshal tests the interlock before opening.
Wet floors, cleaning and GFCI
Commercial kitchens are washed down, so receptacles need GFCI protection and weather-resistant or listed covers where water reaches them. Cord-connected equipment that trips GFCIs is diagnosed rather than moved to an unprotected outlet.
Refrigeration and keeping the doors open
Walk-in coolers and freezers hold thousands of dollars of stock, so their circuits are kept separate from cooking loads and clearly labeled. Many owners add a generator inlet or transfer switch for refrigeration, and some health departments require food to be discarded after a set time without temperature control.
How the work is done
- Plan
- Permits
- Install
- Inspect
- Test
What affects the price of restaurant electrical
- Equipment
- Panel
- Hood
- Schedule
- Permits
Restaurant Electrical questions
Why do kitchen GFCIs trip?
Moisture or equipment faults.
Do restaurants need three-phase?
Often for large equipment.
Can work be done after hours?
Yes.
Who coordinates hoods?
Electricians and hood contractors.
What should a restaurant owner have ready before the electrician starts?
The equipment schedule with model numbers, the kitchen layout, the existing service size and panel schedule, and any landlord or health department requirements.
Related work
Part of Commercial Electrical Services. Also see: Commercial Panel Upgrades, Parking Lot Lighting, Office & Tenant Build-Outs.