Aluminum Wiring Remediation

Aluminum wiring remediation makes 1960s and 1970s aluminum branch circuits safe by connecting them to devices with approved aluminum-to-copper connectors or by replacing the circuits. The risk is at connection points, not in the wire runs themselves.

  • Free to call
  • Independent licensed electricians
  • All 50 states + DC
Aluminum Wiring Remediation illustration

When you need aluminum wiring remediation

  • Wire jackets marked “AL” or “ALUMINUM”
  • House built roughly 1965 to 1973
  • Warm outlets or switches
  • Flickering lights or burnt smells
  • Insurer requests remediation

Why aluminum connections fail

Aluminum expands and contracts more than copper and forms oxide at connections. Over time, standard devices loosen and overheat at the terminals. Devices marked CO/ALR were designed for aluminum, but many homes have standard ones.

Remediation methods

Pigtailing attaches a short copper wire to each aluminum conductor with a connector listed for aluminum-to-copper, then connects the copper to the device. Some connectors are crimped with a special tool; others are twist or push style listed for aluminum. Full replacement is the other option.

What to check

The electrician checks every connection point, including outlets, switches, fixtures and the panel. Large aluminum feeders, such as to a range or subpanel, are common and acceptable when terminated properly.

Signs of failing aluminum connections

Warm cover plates, flickering lights, outlets that stop working and burning smells are warning signs. Connections at switches, outlets and light fixtures should be inspected.

Insurance documentation

Insurers may ask for documentation of remediation. Keep invoices and the electrician’s description of methods used.

How the work is done

  1. Confirm aluminum branch wiring
  2. Inspect every device and junction
  3. Pigtail with listed connectors
  4. Replace damaged devices
  5. Document for insurers

What affects the price of aluminum wiring remediation

  • Number of connection points
  • Connector type
  • Damaged devices
  • Access to boxes
  • Full replacement vs. remediation

Aluminum Wiring Remediation questions

Is all aluminum wiring bad?

No. Large aluminum service and feeder conductors are common. The concern is small branch circuit wiring from the 1960s and 70s.

Are standard wire nuts OK for aluminum?

Only connectors listed for aluminum-to-copper should be used.

Does aluminum wiring affect home sales?

Inspectors flag it, and buyers or insurers often ask for remediation documentation.

Can I replace outlets myself?

Aluminum connections need specific connectors and tools. Use a licensed electrician.

Related work

Part of House Rewiring. Also see: Knob and Tube Replacement, Dedicated Circuit Installation, Kitchen Remodel Wiring.

Free to call · All 50 states + DC

Talk to a licensed electrician

Describe the problem and get connected with an independent licensed electrician who serves your area.

Call (855) 679-2483

By calling, you agree to be connected with an independent electrician, who may call or text you back about your request at the number you call from. Calls may be recorded for quality and routing. Consent is not a condition of any purchase, and you can opt out at any time; message and data rates may apply. Privacy policy.

Call (855) 679-2483

Free referral to independent electricians. By calling you consent to a callback or text and call recording. Details